Chapter 19
Timber and glulam checks
This chapter explains how Statiko checks a solid timber or glulam beam at the ultimate limit state. You see where every factor in a timber check comes from (kmod, kh, ksys, γM, kcr, kcrit and kc,90), which inputs drive them, and what each check card means. The basis is EN 1995-1-1:2004 + A1:2008. Serviceability, with the final deflection and kdef, is in Chapter 21, and fire is in Chapter 22.
Kernel paths in this chapter are under engineering/src/commonMain/kotlin/statiko/engineering/ unless they start with verification/, which is under engineering/src/jvmAndAndroidMain/kotlin/statiko/engineering/.
How the checks run
For every ultimate limit state combination (EN 1990 6.10a, 6.10b, 6.10b with Ginf, 6.10 and 6.10 with Ginf under the Serbian annex, and Custom), Statiko takes the bending moment, shear force and torque at every station of the finite-element result (Chapter 16) and the support reactions. It then checks a rectangular section by elementary stresses against design strengths. Five checks run: bending, shear, torsion, lateral-torsional buckling and bearing. Each check keeps its worst station. Across combinations, the governing combination is the one with the largest utilisation.
Only ultimate limit state combinations govern these checks. Serviceability and fire combinations never do. The Unit expression is used only when the beam has no ultimate limit state combination.
Source: ai/architecture/engineering-rules.md, Timber member factor boundary; kernel timber/TimberUlsCombination.kt:5-16, timber/TimberGoverningCombinationSelector.kt:6-25.
What you enter
- Material grade. C14, C18, C24 or C30 from EN 338:2016, or GL24c, GL24h, GL28c, GL28h, GL30c or GL30h from EN 14080:2013. Each grade carries its characteristic strengths, stiffnesses and densities. For example, C24 has fm,k = 24 MPa, fv,k = 4.0 MPa, fc,90,k = 2.5 MPa and E0,05 = 7 400 MPa.
- Section. A rectangle b × h.
- Design code. The design country sets γM: 1.30 for solid timber and 1.25 for glulam (Eurocode, Sweden, Serbia), or 1.35 and 1.30 (Denmark). A Custom design country takes your own values.
- Service class 1, 2 or 3, and the system factor ksys: 1.0, 1.1 or 1.2.
- Load duration for each action: Permanent, Long-term, Medium-term, Short-term or Instantaneous.
- Stability stiffness for lateral-torsional buckling (see below).
- Lateral restraint of the top flange, and the bearing length lb on every Fixed, Pinned or Roller support (Chapter 8).
Source: kernel project/src/commonMain/kotlin/statiko/project/domain/material/TimberGradeType.kt (EN 338:2016, EN 14080:2013); design/materialFactorPresets.kt:24-29; EN 1995-1-1 2.4.1 Table 2.3; spec/beam/supports.md rule 30.
Design strength factors
Load duration and kmod
An action takes part in a combination when its coefficient in that combination is not zero. Every participating action needs exactly one load duration; a missing or duplicated duration makes the timber checks Invalid input. The governing duration is the shortest duration among the participating actions, as EN 1995-1-1 3.1.3(2) requires. kmod then comes from Table 3.1 for solid timber and glulam:
| Service class | Permanent | Long-term | Medium-term | Short-term | Instantaneous |
|---|---|---|---|---|---|
| 1 and 2 | 0.60 | 0.70 | 0.80 | 0.90 | 1.10 |
| 3 | 0.50 | 0.55 | 0.65 | 0.70 | 0.90 |
Source: EN 1995-1-1 3.1.3, Table 3.1; kernel timber/TimberDesignFactorResolver.kt:54-72, :87-103.
Size factor kh
A shallow section gets a higher bending strength. With h the section depth:
timber/TimberRectangularSection.kt:9-13timber/TimberRectangularSection.kt:14-17Design strengths
timber/TimberBeamUtilizationCalculator.kt:43-44timber/TimberBeamUtilizationCalculator.kt:45-46Bending, shear and torsion
Bending
The beam bends about one axis, so the bending check is the uniaxial form of EN 1995-1-1 6.1.6:
timber/TimberBeamUtilizationCalculator.kt:47, :54Shear and the crack factor kcr
Shear uses the peak shear stress of a rectangle on the effective width bef = kcr · b, which allows for drying cracks:
timber/TimberRectangularSection.kt:20-22, timber/TimberBeamUtilizationCalculator.kt:55-75The design country sets kcr:
| Design country | kcr in Statiko |
|---|---|
| Eurocode | 0.67 |
| Denmark | 1.0 (DS/EN 1995-1-1 DK NA:2024 6.1.7(2)) |
| Serbia | 0.67, the same value as Eurocode |
| Sweden | Shear Unavailable: EKS 12 ties kcr to rain and sun exposure, which the input does not hold |
| Custom | Your value, above 0 and at most 1.0; shear Unavailable until you enter it |
Source: kernel timber/TimberShearCrackFactorResolver.kt:6-19, timber/TimberShearCrackFactor.kt:8-14.
Statiko includes every load near a support in the shear force. The reduction of EN 1995-1-1 6.1.7(3) is not available in this version.
Torsion
The torsional shear stress is τtor,d = |T| / Wtor, with the torque T of the torsion analysis and Wtor = h · b² / (3 + 1.8 · b/h). This torsion modulus is the kernel's own; EN 1995-1-1 gives none (timber/TimberBeamUtilizationCalculator.kt:49-53). With h the larger and b the smaller side, it is checked against the shear strength raised by the shape factor:
timber/TimberBeamUtilizationCalculator.kt:52-53, :79Lateral-torsional buckling
When the top flange is laterally restrained, kcrit = 1.0 (EN 1995-1-1 6.3.3(5)) and the check is the bending check. Otherwise Statiko uses the critical moment Mcr of the member, the lowest eigenvalue of the buckling problem in Chapter 17, rather than the effective lengths of Table 6.1.
Mcr needs fifth-percentile stiffnesses. The material carries their basis:
- Rectangular softwood: G0,05 = E0,05 / 16, from Swedish Wood, Design of timber structures 1 (2016) p. 86, and Centrum Hout, Houteigenschappen (2014/3) p. 2. This is an industry source, not a Eurocode value. The grades C14 to C30 use it.
- Declared: G0,05 with its source. Glulam always needs a declared value; the grades GL24c to GL30h declare G0,05 = 540 MPa from EN 14080:2013 Tables 4 and 5.
- No basis: lateral-torsional buckling is Unavailable, and the other checks still run. A project saved before this version keeps the basis it was saved with.
timber/TimberBeamUtilizationCalculator.kt:164-174timber/TimberBeamUtilizationCalculator.kt:175-179timber/TimberBeamUtilizationCalculator.kt:180-181The slenderness uses the characteristic strength fm,k alone; ksys enters only fm,d.
Source: kernel timber/TimberStabilityStiffnessResolver.kt:11-57, verification/TimberBeamChecks.kt:241-291.
Bearing at the supports
Bearing is compression perpendicular to the grain over each Fixed, Pinned or Roller support. Statiko centres the contact length lb you enter on the support. At each side, the contact length is extended by the smallest of 30 mm, lb, half the clear distance l1 to the next contact, or the distance to the member end (Figure 6.2). The member starts and ends at its first and last support, so at an end support the outer extension is 0 and only the inner side is extended.
timber/TimberBearingCalculator.kt:57-89timber/TimberBearingCalculator.kt:46-47timber/TimberBearingCalculator.kt:91-95kh and ksys do not enter the bearing strength. kc,90 is 1.0 unless every clear distance l1 to an adjacent contact is at least 2h (one distance at an end support, two at an internal one) and the material qualifies; a single bearing with no neighbour keeps 1.0 (timber/TimberBearingCalculator.kt:146-156). Then kc,90 is 1.5 for solid softwood, and 1.75 for glulam when lb ≤ 400 mm (6.1.5(4), discrete supports). The governing support is the one with the largest utilisation.
A support without a bearing length makes the check Not checked with "Support B has no bearing length." A support that carries a moment (a fixed end) makes the check Unsupported.
Source: kernel timber/TimberBearingCalculator.kt:141-156, verification/TimberBeamChecks.kt:169-239; spec/beam/supports.md rule 30.
What you see
The timber checks column shows Bending, Shear, Torsion, Lateral-torsional buckling and Bearing, and a timber utilisation summary. Each check shows its utilisation, governing combination and position. Its detail lists the terms: kmod with the service class and governing duration, kh, ksys, γM, the characteristic and design strengths and the stress. Shear adds kcr and bef. Torsion adds kshape. Lateral-torsional buckling adds σm,crit, λrel,m, kcrit and Mcr. Bearing adds lef, Aef, kc,90 and the reaction. The report prints the same result; it never recalculates.
A check that cannot run reads Unavailable with its reason, Not checked, Unsupported, Invalid input or Calculation failed. None of these counts as a pass. A utilisation above 1.0 is a failed check that is still printed in full.
Limits of this version
- Rectangular solid timber and glulam only, bending about one axis; axial force is outside the beam check.
- Hardwood (D) strength classes are not available in this version.
- No National Annex factor is inferred from a country name; Custom values are yours to source.
- The eligibility of ksys is not checked.
- Bearing uses the discrete-support factors only; the continuous-support values of 6.1.5(3) are not used.