Chapter 24

Notation, units and glossary

This chapter is the reference for the symbols, units and words Statiko shows on screen and in the PDF report. Use it when a symbol in a check, a graph or the report is unfamiliar, when you want to change units, or when you need to know which direction counts as positive. Every symbol is drawn from one notation source shared by the app and the report, so a symbol means the same thing everywhere.

How symbols are written

  • Symbols are typeset with real subscripts and superscripts, for example MEd or γM0, never with visible underscores.
  • Negative numbers use the true minus “−”; there is no plus sign on positive values. Input fields accept both - and −.
  • Green and red appear only with a real Pass or Fail and always with the word. Unsupported, Unavailable, Invalid input and Failed calculation stay neutral and distinct.
  • Utilisation is shown as a percentage with the ratio η beside it, for example 86.2 % and η = 0.862.
  • In the report, a label made of two parts is joined with “ · ”, for example “Gk · Dead Load”.

Source: CODING_GUIDELINES.md, Engineering notation and reports; spec/beam/structural-system-drawing.md rules 11, 12; spec/beam/checks-column.md rule 7; spec/beam/report.md rules 34, 58.

Axes and sign convention

The report's Basis of design states the convention: “Loads and displacement are positive downward; moments are positive counter-clockwise; sagging moment is positive and drawn up. Positive shear is drawn up.”

  • x runs along the beam; y and z are the transverse directions. The structural model offers the “y–y elevation” (strong axis, z displacement) and the “z–z elevation” (weak axis, y displacement).
  • In the drawing, reaction badges show magnitudes and the arrow shows the direction: a positive force points up and a positive moment turns anticlockwise. Tables and the report keep the signed components.
  • Load values keep their sign, for example 24.50 kN/m and −16.20 kN/m.
  • Supports restrain: fixed w and φ; pinned u and w; roller w.
  • In the concrete flexure figure, sagging compresses the top face and hogging the bottom.

Source: resources ReportStringsEn axes and sign convention text; spec/beam/structural-system-drawing.md rules 11, 13; spec/beam/concrete-report.md rule 9; resources notation AnalysisNotation.kt.

Units

Choose units in Settings › Units. The Defaults tab holds the Metric or Imperial preset; the Advanced tab can “Override input, display and PDF units per app area. Unset fields use the Defaults tab.” The report uses the same units and decimals (see Chapter 14).

QuantityMetric defaultImperial defaultDecimalsChoices
Lengthmft2mm, cm, dm, m, in, ft, yd
Displacementmmin1mm, cm, dm, m, in, ft, yd
ForcekNkip2N, kN, lbf, kip
Force / LengthkN/mlbf/ft2N/mm, N/m, kN/m, lbf/in, lbf/ft
MomentkNmkip·ft2Nmm, Nm, kNm, lbf·ft, lbf·in, kip·ft
Inertiacm⁴in⁴0mm⁴, cm⁴, m⁴, in⁴, ft⁴
Self weightkg/mlb/ft2kg/m, g/m, lb/ft, oz/ft
Densitykg/m³lb/ft³0kg/m³, g/m³, lb/ft³, lb/in³
StressMPaksi1Pa, kPa, MPa, psi, ksi
Timeminmin0s, min, h
Temperature°C°F0°C, K, °F
Rotationradrad8mrad, rad, °
Areacm²in²2mm², cm², m², in², ft², yd²
Warping constantcm⁶in⁶2m⁶, cm⁶, mm⁶, in⁶, ft⁶
Section moduluscm³in³2mm³, cm³, m³, in³, ft³
FrequencyHzHz2Hz, kHz
Bending stiffnessMNm²kip·in²2Nm², kNm², MNm², kip·in²

The Advanced tab groups overrides by area: Cross-section / detailing (length, recommended mm or in), Supports (length), Loads (length, force, force per length, moment, self-weight) and Results (displacement, stress, rotation). The Results area sets rotation to mrad with 2 decimals, which is why the Rotation graph shows mrad.

Other units you may see: ‰ for concrete strains, 1/m for the steel section factor Am/V, W/(m·K) and J/(kg·K) for thermal properties. The AI agent interface uses SI base units only (see Chapter 23).

Source: reports/units UnitDisplayQuantity.kt and UnitPreferenceArea.kt; project unit MeasurementUnit.kt; resources UnitStringsEn.

Symbols: actions, combinations and results

SymbolMeaningUnitWhere
Gk, QkCharacteristic permanent and variable actionkN, kN/m, kNmLoads, report 3.1
γG, γQ, γG,sup, γG,infPartial factors on actions–Design code, report 3.2
ξ·γG,supReduced permanent factor of 6.10b–Report 3.2
ψ0, ψ1, ψ2Combination, frequent and quasi-permanent factors–Report 3.2
KFIConsequence-class factor–Basis of design
6.10a, 6.10bEN 1990 ULS (STR/GEO) combinations–Combination names
6.10EN 1990 ULS (STR/GEO) combination of the Serbian annex–Combination names
6.14b, 6.15b, 6.16bCharacteristic, frequent, quasi-permanent SLS combinations–Combination names
6.11a/bAccidental (fire) combination–Fire
P, M, qPoint load, moment, distributed loadkN, kNm, kN/mLoad cards, report drawing
x, x1, x2Position along the beam; start and end of a loadmLoads, graphs
ey, ezLoad eccentricitiesmmLoad cards, report 3.1
LSpan; L/n deflection limitmDrawing, Design code
V, M, θ, δ, TShear, moment, rotation, deflection, torsionkN, kNm, mrad, mm, kNmResult graphs
ϕAngle of twistmradTorsion graph (Twist)
f1, fnFirst and n-th natural frequencyHzNatural Frequency graph, Eigenfrequencies
flimFrequency limit from the project settingsHzEigenfrequencies
w, wlimDeflection and its limitmmDisplacements
uinst, ufinInstantaneous and final deflection (timber)mmDeflection graph, Displacements, report 6.1
MEd, VEd, TEdDesign moment, shear, torquekNm, kN, kNmChecks
McrElastic critical moment for lateral-torsional bucklingkNmMoment graph header, LTB check
ηUtilisation ratio–Every check

Source: resources notation CombinationNotation.kt, ActionsNotation.kt, AnalysisNotation.kt, SectionNotation.kt, BeamCheckNotation.kt.

Symbols: steel and timber

SymbolMeaningUnitWhere
fy, fuSteel yield and ultimate strengthMPaReport 2.1, steel checks
γM0, γM1, γM2Steel partial factors: cross-section, instability, fracture–Report 2.1; γM1 in LTB
ε, c/tClassification strain factor, plate slenderness–Report 2.2 classification
Wpl, Wel,min, WeffPlastic, minimum elastic and effective section moduluscm³Bending check
Mc,RdBending resistancekNmBending check
Av,z, Vpl,Rd, Vpl,T,RdShear area, plastic shear resistance (with torsion)cm², kNShear check
hw, tw, η, 72 ε/ηWeb height and thickness, shear factor, web slenderness limitmm, –Shear Buckling Resistance
ρ, My,V,RdHigh-shear reduction and reduced moment resistance–, kNmBending check, report 5.3
αLT, λ̄LT, ΦLT, χLT, Mb,RdLTB imperfection factor, relative slenderness, Φ, reduction factor, buckling resistance–, kNmLTB check
TRd, τt,Ed, τw,EdTorsion resistance, St Venant and warping shear stresskNm, MPaTorsion check
Mw,Ed, Mz,EdWarping moment, minor-axis momentkNmBending and LTB cards
A, Iy, Iz, It, Iw, Wel,y, Wpl,y, iy, izArea, second moments, torsion and warping constants, section moduli, radii of gyrationcm², cm⁴, cm⁶, cm³, cmReport 2.2, Profile view
fm,k, fv,k, fc,90,kTimber characteristic bending, shear and perpendicular compression strengthMPaReport 2.1
E0,mean, E0,05, ρmeanTimber stiffness and densityMPa, kg/m³Report 2.1
γM, γ3Timber partial factors–Report 2.1, Design code
kmod, kh, ksys, kdefModification, size, system and deformation factors–Timber checks, report 2.1
σm,y,d, fm,dDesign bending stress and strengthMPaTimber Bending
τv,d, fv,d, kcr, befDesign shear stress and strength, crack factor, effective widthMPa, –, mmTimber Shear
τtor,d, kshapeTorsion stress, shape factorMPa, –Timber Torsion
σm,crit, λrel,m, kcritCritical bending stress, relative slenderness, LTB factorMPa, –Timber LTB
lef, Aef, kc,90, σc,90,d, fc,90,dEffective bearing length and area, bearing factor, stress and strengthmm, mm², –, MPaBearing check

Source: resources notation BeamCheckNotation.kt, SectionNotation.kt, TimberNotation.kt, DesignCodeNotation.kt.

Symbols: concrete and fire

SymbolMeaningUnitWhere
fck, Ecm, fcdConcrete characteristic and design strength, modulusMPaConcrete report 2.1, Bending
fyk, fydReinforcement characteristic and design yield strengthMPaConcrete report 2.1, Bending
γC, γS, αcc, αct, cot θConcrete partial factors, coefficients, strut angle–Concrete Basis of design
d, As,t, As,cEffective depth, tension and compression reinforcementmm, mm²Concrete section properties
cmin,dur, ΔcdevDurability cover, execution deviationmmConcrete report 2.1
x, εcu, εs,max, Cc, Cs, TsNeutral-axis depth, strains, internal forcesmm, ‰, kNBending + and −, flexure figure
VRd,c, VRd,s, VRd,maxShear resistances without links, with links, strutkNConcrete Shear
σc, σsConcrete and reinforcement stressMPaStresses
wk, sr,maxCrack width, maximum crack spacingmmCrack width
lbd, l0Anchorage and lap lengthmmAnchorage, Laps
Efi,d, Rfi,d,0, μ0Fire design effect, resistance at time zero, degree of utilisationkNm, –Steel fire
κ1, κ2, γM,fiFire adaptation factors and partial factor–Steel fire
θa, θa,crSteel temperature and critical temperature°CSteel fire
Am/VSection factor1/mSteel fire
dp, λp, cp, ρpProtection thickness, conductivity, specific heat, densitymm, W/(m·K), J/(kg·K), kg/m³Steel fire protection
Mfi,t,Rd, Vfi,t,Rd, Mb,fi,t,Rd, χLT,fiResistances in fire at time tkNm, kN, –Steel resistance method
dchar,n, def, bfi, hfiNotional and effective charring depth, residual width and heightmmTimber fire
kmod,fi, fm,d,fi, fv,d,fiFire modification factor and design strengths–, MPaTimber fire
hpCladding thicknessmmTimber fire cladding
bmin, a, aminMinimum width, axis distance and its minimummmConcrete fire
R30 … R240Required fire resistance classminFire inputs

Source: resources notation ConcreteNotation.kt, SteelNotation.kt, TimberNotation.kt; spec/beam/concrete-report.md rules 4–9; spec/beam/fire.md rules 20–47.

State words

WordMeaning
Results current · <combination>The shown result belongs to the current input
Calculating…A calculation is running; results update automatically
Results outdatedYou changed the input after the shown result
Invalid inputA field holds a value that cannot be calculated
Not calculatedThere is nothing to calculate yet, for example no loads and self-weight off
Calculation unsupported / failed / unavailableThe engine does not cover the model, broke on it or could not run
Pass / FailA real verdict with its utilisation
GoverningThe evaluated check with the greatest utilisation
Not evaluated / Not relevantThe check does not apply to this beam; never a pass
Unsupported / Unavailable / Failed calculationA check the engine does not cover, could not give, or broke on
Not checkedThe report's word for a check without a verdict
Resistance satisfied / not satisfied; Partial resultFire verdicts

Source: spec/beam/workspace-shell.md rules 20–25; spec/beam/checks-column.md rules 9, 12, 14; spec/beam/report.md rule 11; spec/beam/fire.md rules 10, 42.